AltiWare OE 3.5A Patch 2
==================================================
05/15/2000

This patch is for AltiWare OE 3.5A users only.


Patch purpose:

        1. System keeps paging user who has new message(s) in his mailbox, until maximum
           retry count is reached or the user logins to his mailbox. After logging into
           your mailbox all outcall notification flags for all messages are reset. 
           In other words, the system will stop paging you until a new message is left.

        2. Voice mail is now left in the target extension mailbox. for example:
           1) Ext A forwards all calls to Ext B. 
           2) Ext C calls Ext A. Ext B pick up the call (because Ext A is all call
              forwarded to Ext B), and blind xfers the call to Ext D, but Ext D is 
              ring no answer.
           3) The message should be left in Ext D voice mail box.

        3. Support T1 Centrex Transfer.

        4. (Fixed) In some installations, when a IP trunk caller hangs up as soon as he 
           gets the voice mail greeting of an extension, or an empty voice mail is forward
           to an E-mail client, an arbitrarily large message is generated and this causes 
           voice mail and email delivery to be delayed for several hours.

        5. (Fixed) In some installations, one or two IP trunks become unusable, even the
           status shows 'Idle'.

        6. In OE 3.5A with Patch 1, AltiWare seizes analog trunks every 20 seconds to check
           trunk status. This causes potential glare condition or missing caller ID. 
           This problem has been corrected in patch 2.
          

To use Continue Pager:
        1. Set "message notification by calling a Pager" from "Messaging 2" in 
           extension configuration.
        2. Set "Maximum Retry Count" and "Retry Interval" from "Messaging" in 
           System configuration. 
        3. System will keep paging the user until the user logs in to his voice 
           mail box or maximum retry counter is reached.


Installation Instructions:
        1. Stop AltiGen Switching Service.
        2. Backup existing altiserv.exe and maentry.exe from \altiserv\exe\ directory.
        3. Run \Update\Patch\OE35A_Patch2.exe from AltiWare OE 3.5A CD.
        4. Reboot system or restart AltiGen Switching Service.